Particle Characterisation

Beckman Coulter LSTM 13 320 Series Laser Diffraction Particle Size Analyzers

The Latest in Laser Diffraction Particle Size Analysis Comes

The Beckman Coulter LS 13 320 Series is a system of multifunctional particle characterization tools. Its patented state-of-the-art, laser-based technology permits analysis of particles without the risk of missing either the largest or the smallest particles in a sample. The LS 13 320 technology is based on Fraunhofer and Mie theories of light scattering. The LS 13 320 differs from other laser-based instruments by virtue of its wide dynamic size range, number of size channels and sample measurement options.

The LS 13 320 Series Utilizes Unique Patented Polarization Intensity Differential scattering (PIDS) technology to measure particle in submicron range up to 20 nm and the patented Tornado dry powder- dispersing system. The LS 13 320 uses reverse Fourier optics incorporated in a patented fiber optic spatial filter system and a binocular lens system. This enables the LS 13 320 to optimize light scattering measurement across the widest dynamic range, from 0.017 µm to 2000 µm, in a single scan with no extrapolation. The LS 13 320 Delivers Excellent Data Reproducibility, typically better than 1%.

Product Features

  • Single Wavelength LS 13320: Dynamic Range – 0.1 to 2000 µm
  • Multi wavelength (using Patented PIDS) LS 13320: Dynamic Range – 0.017-2000 µm
  • Patented Tornado dry powder dispersing system
  • Patented fiber optic spatial filter system
  • 'Auto Dock' - Unique module change system
  • Change between wet and dry to wet again in less than a minute
  • User friendly software and advanced software security features
  • Software Security and 21 CFR Part 11 Regulatory Compliance (optional)
  • Certification Program to ensure instrument performance (optional)
  • V-Check (IQ, OQ, PQ) instrument validation (optional)

View Other Products